Friday, August 24, 2012

Sensor detects glucose in saliva and tears for diabetes testing

Sensor detects glucose in saliva and tears for diabetes testing [ Back to EurekAlert! ] Public release date: 23-Aug-2012
[ | E-mail | Share Share ]

Contact: Emil Venere
venere@purdue.edu
765-494-4709
Purdue University

WEST LAFAYETTE, Ind. Researchers have created a new type of biosensor that can detect minute concentrations of glucose in saliva, tears and urine and might be manufactured at low cost because it does not require many processing steps to produce.

"It's an inherently non-invasive way to estimate glucose content in the body," said Jonathan Claussen, a former Purdue doctoral student and now a research scientist at the U.S. Naval Research Laboratory. "Because it can detect glucose in the saliva and tears, it's a platform that might eventually help to eliminate or reduce the frequency of using pinpricks for diabetes testing. We are proving its functionality."

Claussen and Purdue doctoral student Anurag Kumar led the project, working with Timothy Fisher, a Purdue professor of mechanical engineering, D. Marshall Porterfield, a professor of agricultural and biological engineering, and other researchers at the university's Birck Nanotechnology Center.

Findings are detailed in a research paper appearing online this week in the journal Advanced Functional Materials.

"Most sensors typically measure glucose in blood," Claussen said. "Many in the literature aren't able to detect glucose in tears and the saliva. What's unique is that we can sense in all four different human serums: the saliva, blood, tears and urine. And that hasn't been shown before."

The paper, featured on the journal's cover, was written by Claussen, Kumar, Fisher, Porterfield, and Purdue researchers David B. Jaroch, M. Haseeb Khawaja, and Allison B. Hibbard.

The sensor has three main parts: layers of nanosheets resembling tiny rose petals made of a material called graphene, which is a single-atom-thick film of carbon; platinum nanoparticles; and the enzyme glucose oxidase.

Each petal contains a few layers of graphene stacked on each other. The edges of the petals have dangling, incomplete chemical bonds, defects where the platinum nanoparticles can attach. Electrodes are formed by combining the nanosheet petals and platinum nanoparticles. Then the glucose oxidase attaches to the platinum nanoparticles. The enzyme converts glucose to peroxide, which generates a signal on the electrode.

"Typically, when you want to make a nanostructured biosensor you have to use a lot of processing steps before you reach the final biosensor product," Kumar said. "That involves lithography, chemical processing, etching and other steps. The good thing about these petals is that they can be grown on just about any surface, and we don't need to use any of these steps, so it could be ideal for commercialization."

In addition to diabetes testing, the technology might be used for sensing a variety of chemical compounds to test for other medical conditions.

"Because we used the enzyme glucose oxidase in this work, it's geared for diabetes," Claussen said. "But we could just swap out that enzyme with, for example, glutemate oxidase, to measure the neurotransmitter glutamate to test for Parkinson's and Alzheimer's, or ethanol oxidase to monitor alcohol levels for a breathalyzer. It's very versatile, fast and portable."

The technology is able to detect glucose in concentrations as low as 0.3 micromolar, far more sensitive than other electrochemical biosensors based on graphene or graphite, carbon nanotubes and metallic nanoparticles, Claussen said

"These are the first findings to report such a low sensing limit and at the same time such a wide sensing range," he said.

The sensor is able to distinguish between glucose and signals from other compounds that often cause interference in sensors: uric acid, ascorbic acid and acetaminophen, which are commonly found in the blood. Unlike glucose, those compounds are said to be electroactive, which means they generate an electrical signal without the presence of an enzyme.

Glucose by itself doesn't generate a signal but must first react with the enzyme glucose oxidase. Glucose oxidase is used in commercial diabetes test strips for conventional diabetes meters that measure glucose with a finger pinprick.

###

The research has been based at Purdue's Birck Nanotechnology Center at the university's Discovery Park. The research has been funded by the U.S. Office of Naval Research and the National Science Foundation.

Writer: Emil Venere, 765-494-4709, venere@purdue.edu

Sources: Jonathan Claussen, 202-767-3560, jonathan.claussen@gmail.com

Anurag Kumar, kumar.anuragsharma@gmail.com

Timothy Fisher, 765-494-5627, tsfisher@purdue.edu

D. Marshall Porterfield, 765-494-1190, porterf@purdue.edu

Related websites:

Timothy Fisher: https://engineering.purdue.edu/ME/People/ptProfile?id=28558

IMAGE CAPTION:

These color-enhanced scanning electron microscope images show nanosheets resembling tiny rose petals. The nanosheets are key components of a new type of biosensor that can detect minute concentrations of glucose in saliva, tears and urine. The technology might eventually help to eliminate or reduce the frequency of using pinpricks for diabetes testing. (Jeff Goecker, Purdue University)

A publication-quality image is available at http://news.uns.purdue.edu/images/2012/fisher-sensor.jpg

ABSTRACT

Nanostructuring Platinum Nanoparticles on Multilayered Graphene Petal Nanosheets for Electrochemical Biosensing Jonathan C. Claussen2, Anurag Kumar1,David B. Jaroch3, M. Haseeb Khawaja1, Allison B. Hibbard1, D. Marshall Porter?eld,2, 3, and Timothy S. Fisher1

1 Birck Nanotechnology Center, School of Mechanical Engineering, Purdue University

2Birck Nanotechnology Center, Department of Agricultural and Biological Engineering, Purdue University School of Mechanical Engineering

3Birck Nanotechnology Center, Weldon School of Biomedical Engineering, Purdue University

Hybridization of nanoscale metals and carbon nanotubes into composite nanomaterials has produced some of the best-performing sensors to date. The challenge remains to develop scalable nanofabrication methods that are amenable to the development of sensors with broad sensing ranges. A scalable nanostructured biosensor based on multilayered graphene petal nanosheets (MGPNs), Pt nanoparticles, and a biorecognition element (glucose oxidase) is presented. The combination of zero-dimensional nano-particles on a two-dimensional support that is arrayed in the third dimension creates a sensor platform with exceptional characteristics. The versatility of the biosensor platform is demonstrated by altering biosensor performance (i.e., sensitivity, detection limit, and linear sensing range) through changing the size, density, and morphology of electrodeposited Pt nanoparticles on the MGPNs. This work enables a robust sensor design that demonstrates exceptional performance with enhanced glucose sensitivity (0.3 M detection limit, 0.01 mM linear sensing range), a long stable shelf-life (> 1 month), and a high selectivity over electroactive, interfering species commonly found in human serum samples.



[ Back to EurekAlert! ] [ | E-mail | Share Share ]

?


AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert! system.


Sensor detects glucose in saliva and tears for diabetes testing [ Back to EurekAlert! ] Public release date: 23-Aug-2012
[ | E-mail | Share Share ]

Contact: Emil Venere
venere@purdue.edu
765-494-4709
Purdue University

WEST LAFAYETTE, Ind. Researchers have created a new type of biosensor that can detect minute concentrations of glucose in saliva, tears and urine and might be manufactured at low cost because it does not require many processing steps to produce.

"It's an inherently non-invasive way to estimate glucose content in the body," said Jonathan Claussen, a former Purdue doctoral student and now a research scientist at the U.S. Naval Research Laboratory. "Because it can detect glucose in the saliva and tears, it's a platform that might eventually help to eliminate or reduce the frequency of using pinpricks for diabetes testing. We are proving its functionality."

Claussen and Purdue doctoral student Anurag Kumar led the project, working with Timothy Fisher, a Purdue professor of mechanical engineering, D. Marshall Porterfield, a professor of agricultural and biological engineering, and other researchers at the university's Birck Nanotechnology Center.

Findings are detailed in a research paper appearing online this week in the journal Advanced Functional Materials.

"Most sensors typically measure glucose in blood," Claussen said. "Many in the literature aren't able to detect glucose in tears and the saliva. What's unique is that we can sense in all four different human serums: the saliva, blood, tears and urine. And that hasn't been shown before."

The paper, featured on the journal's cover, was written by Claussen, Kumar, Fisher, Porterfield, and Purdue researchers David B. Jaroch, M. Haseeb Khawaja, and Allison B. Hibbard.

The sensor has three main parts: layers of nanosheets resembling tiny rose petals made of a material called graphene, which is a single-atom-thick film of carbon; platinum nanoparticles; and the enzyme glucose oxidase.

Each petal contains a few layers of graphene stacked on each other. The edges of the petals have dangling, incomplete chemical bonds, defects where the platinum nanoparticles can attach. Electrodes are formed by combining the nanosheet petals and platinum nanoparticles. Then the glucose oxidase attaches to the platinum nanoparticles. The enzyme converts glucose to peroxide, which generates a signal on the electrode.

"Typically, when you want to make a nanostructured biosensor you have to use a lot of processing steps before you reach the final biosensor product," Kumar said. "That involves lithography, chemical processing, etching and other steps. The good thing about these petals is that they can be grown on just about any surface, and we don't need to use any of these steps, so it could be ideal for commercialization."

In addition to diabetes testing, the technology might be used for sensing a variety of chemical compounds to test for other medical conditions.

"Because we used the enzyme glucose oxidase in this work, it's geared for diabetes," Claussen said. "But we could just swap out that enzyme with, for example, glutemate oxidase, to measure the neurotransmitter glutamate to test for Parkinson's and Alzheimer's, or ethanol oxidase to monitor alcohol levels for a breathalyzer. It's very versatile, fast and portable."

The technology is able to detect glucose in concentrations as low as 0.3 micromolar, far more sensitive than other electrochemical biosensors based on graphene or graphite, carbon nanotubes and metallic nanoparticles, Claussen said

"These are the first findings to report such a low sensing limit and at the same time such a wide sensing range," he said.

The sensor is able to distinguish between glucose and signals from other compounds that often cause interference in sensors: uric acid, ascorbic acid and acetaminophen, which are commonly found in the blood. Unlike glucose, those compounds are said to be electroactive, which means they generate an electrical signal without the presence of an enzyme.

Glucose by itself doesn't generate a signal but must first react with the enzyme glucose oxidase. Glucose oxidase is used in commercial diabetes test strips for conventional diabetes meters that measure glucose with a finger pinprick.

###

The research has been based at Purdue's Birck Nanotechnology Center at the university's Discovery Park. The research has been funded by the U.S. Office of Naval Research and the National Science Foundation.

Writer: Emil Venere, 765-494-4709, venere@purdue.edu

Sources: Jonathan Claussen, 202-767-3560, jonathan.claussen@gmail.com

Anurag Kumar, kumar.anuragsharma@gmail.com

Timothy Fisher, 765-494-5627, tsfisher@purdue.edu

D. Marshall Porterfield, 765-494-1190, porterf@purdue.edu

Related websites:

Timothy Fisher: https://engineering.purdue.edu/ME/People/ptProfile?id=28558

IMAGE CAPTION:

These color-enhanced scanning electron microscope images show nanosheets resembling tiny rose petals. The nanosheets are key components of a new type of biosensor that can detect minute concentrations of glucose in saliva, tears and urine. The technology might eventually help to eliminate or reduce the frequency of using pinpricks for diabetes testing. (Jeff Goecker, Purdue University)

A publication-quality image is available at http://news.uns.purdue.edu/images/2012/fisher-sensor.jpg

ABSTRACT

Nanostructuring Platinum Nanoparticles on Multilayered Graphene Petal Nanosheets for Electrochemical Biosensing Jonathan C. Claussen2, Anurag Kumar1,David B. Jaroch3, M. Haseeb Khawaja1, Allison B. Hibbard1, D. Marshall Porter?eld,2, 3, and Timothy S. Fisher1

1 Birck Nanotechnology Center, School of Mechanical Engineering, Purdue University

2Birck Nanotechnology Center, Department of Agricultural and Biological Engineering, Purdue University School of Mechanical Engineering

3Birck Nanotechnology Center, Weldon School of Biomedical Engineering, Purdue University

Hybridization of nanoscale metals and carbon nanotubes into composite nanomaterials has produced some of the best-performing sensors to date. The challenge remains to develop scalable nanofabrication methods that are amenable to the development of sensors with broad sensing ranges. A scalable nanostructured biosensor based on multilayered graphene petal nanosheets (MGPNs), Pt nanoparticles, and a biorecognition element (glucose oxidase) is presented. The combination of zero-dimensional nano-particles on a two-dimensional support that is arrayed in the third dimension creates a sensor platform with exceptional characteristics. The versatility of the biosensor platform is demonstrated by altering biosensor performance (i.e., sensitivity, detection limit, and linear sensing range) through changing the size, density, and morphology of electrodeposited Pt nanoparticles on the MGPNs. This work enables a robust sensor design that demonstrates exceptional performance with enhanced glucose sensitivity (0.3 M detection limit, 0.01 mM linear sensing range), a long stable shelf-life (> 1 month), and a high selectivity over electroactive, interfering species commonly found in human serum samples.



[ Back to EurekAlert! ] [ | E-mail | Share Share ]

?


AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert! system.


Source: http://www.eurekalert.org/pub_releases/2012-08/pu-sdg082312.php

gabrielle giffords juliette lewis chelsea handler mitch daniels shirataki noodles john kerry prince fielder

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.